CakeResume 找人才

進階搜尋
On
4 到 6 年
6 到 10 年
10 到 15 年
15 年以上
Avatar of the user.
Avatar of the user.
馬達設計工程師 @鑫元鴻實業股份有限公司
2022 ~ 現在
工程師
一個月內
ANSYS MAXWELL
AutoCad 2D
word
就職中
目前會考慮了解新的機會
全職 / 對遠端工作有興趣
4 到 6 年
逢甲大學(Feng Chia University)
資訊電機工程碩士學位學程
Avatar of Mark Weng.
Avatar of Mark Weng.
Sales Engineer @ABB
2023 ~ 現在
IoT Developer/IoT Solution Architect
兩個月內
翁佑甯 (Mark Weng) 相信程式碼能突破傳統產業的框架。 IT幫 website Kaohsiung,TW [email protected] 技能 Ansys(Ansoft) Maxwell 電磁分析、各式電機最佳化設計 python elasticsearch api Flask web api Django Framework Ansys maxwell script Ruby on Rails、React.js、Vue.js MVC架構、網頁前端開發 ABB LEAP 高壓馬達&發電機線圈放電量測 經歷 中原大學 生物
Ruby on Rails
AutoCAD
ansoft maxwell
就職中
目前沒有興趣尋找新的機會
全職 / 對遠端工作有興趣
6 到 10 年
Chung Yuan Christian University
生物醫學工程
Avatar of Su Wei Sheng.
Avatar of Su Wei Sheng.
Senior Engineer @Powertech Technology Inc.
2021 ~ 現在
Senior Engineer
超過一年
inline device failure analysis by FIB ,SEM,EDS. 4. Optimize recipe inspection or measurement time to improve WPH. 5 .Metrology data monitoring by SPC chart and improvement. Specialist • Shihlin Electric &Engineering Corp SepAugODM & OEM the AC generators in the heavy motorcycle. 2. Using Ansys Maxwell to do magnetic analysis for AC generators. 3. Sketch the stru cture of AC generator by 2D & 3D software. 4. Improve the product process more smoothly. Skill Product WLP bumping process Yield analysis Software Excel, JMP Autocad,Solidworks User Experience Customer support RMA
Excel
autocad
8D analysis
就職中
目前沒有興趣尋找新的機會
全職 / 對遠端工作有興趣
4 到 6 年
國立雲林科技大學 National Yunlin University of Science and Technology
Electrical Engineering

最輕量、快速的招募方案,數百家企業的選擇

搜尋履歷,主動聯繫求職者,提升招募效率。

  • 瀏覽所有搜尋結果
  • 每日可無限次數開啟陌生對話
  • 搜尋僅開放付費企業檢視的履歷
  • 檢視使用者信箱 & 電話
搜尋技巧
1
嘗試搜尋最精準的關鍵字組合
資深 後端 php laravel
如果結果不夠多,再逐一刪除較不重要的關鍵字
2
將須完全符合的字詞放在雙引號中
"社群行銷"
3
在不想搜尋到的字詞前面加上減號,如果想濾掉中文字,需搭配雙引號使用 (-"人資")
UI designer -UX
免費方案僅能搜尋公開履歷。
升級至進階方案,即可瀏覽所有搜尋結果(包含數萬筆覽僅在 CakeResume 平台上公開的履歷)。

職場能力評價定義

專業技能
該領域中具備哪些專業能力(例如熟悉 SEO 操作,且會使用相關工具)。
問題解決能力
能洞察、分析問題,並擬定方案有效解決問題。
變通能力
遇到突發事件能冷靜應對,並隨時調整專案、客戶、技術的相對優先序。
溝通能力
有效傳達個人想法,且願意傾聽他人意見並給予反饋。
時間管理能力
了解工作項目的優先順序,有效運用時間,準時完成工作內容。
團隊合作能力
具有向心力與團隊責任感,願意傾聽他人意見並主動溝通協調。
領導力
專注於團隊發展,有效引領團隊採取行動,達成共同目標。
超過一年
國立交通大學 - 機械工程學系
2018 ~ 2018
專業背景
目前狀態
待業中
求職階段
專業
產業
工作年資
小於 1 年
管理經歷
技能
word
english
powerpoint
excel
LabVIEW
Matlab
ANSYS MAXWELL
語言能力
求職偏好
希望獲得的職位
機械相關工程師
預期工作模式
全職
期望的工作地點
遠端工作意願
對遠端工作有興趣
接案服務
學歷
學校
交通大學
主修科系
機械工程學系
列印

Jia-En Chen(Samuel)


Responsible, Passion, Persevere
Birth Day:1995/07/26
Email:[email protected]
Phone:0912024459

Education



National Chiao Tung University Department of Mechanical Engineering

Nano Engineer Lab

National Sun Yat-sen University Department of  Mechanical and Electro-Mechanical Engineering

Work Experience

Dynamic Class TA  •  

National Chiao Tung University Department of Mechanical Engineering

Feb. 2018 - Jun. 2018


Skill

Professional Field


  • Programming:C, Matlab
  • Apply Software:LabView,  ANSYS Maxwell
  • Professional Field:Statics, Dynamics, Electromagnetic(master degree needed)

Language


  • English (TOEIC 825)

Conference Paper

Novel Electromagnetic Targeting System for Navigating Surgery in Endobronchoscopy


2018 IEEE International Magnetics Conference (INTERMAG), Singapore

Nowadays, lung cancer is one of the common cancers around the world. To increase the survival rate of the patient, early diagnosis is necessary. To achieve this, bronchoscopists usually use Endobronchial Ultrasound for navigating surgery in Endobronchoscopy. However, because the bronchoscopist has to continuously re-navigate/re-target the bronchoscope to collect specimens from the same tumor, the whole navigating/targeting process has to be repeated many times in one surgery. Due to this, navigating/targeting the bronchoscope to correct tumor is still a time-consuming process. Therefore, a more accurately tumor-targeting approach is needed to significantly save time in navigating surgery. To address this issue, recently researchers combined electromagnetic (magnetic-sensor-based)targeting technology with conventional endobronchial ultrasound as a hybrid targeting approach to achieve a more accurate real-time tumor-targeting in Endobronchoscopy . However, when comparing conventional bronchoscope, the bronchoscope with magnetic sensor is more expensive and less compatible. Thus, a cheaper and compatible electromagnetic targeting technology is required. Recently, some researchers demonstrated electromagnetic induction/ magnetic-interaction approaches to target distal screw-hole in intramedullary interlocking-nail surgery We think that these targeting approaches can be modified to develop as a new, cheaper, and compatible electromagnetic targeting technology for general Endobronchoscopy. Hence, in this paper, we demonstrate the electromagnetic targeting system for Endobronchoscopy.


A Novel Targeting System Using Magnetic-Rotating  Method for Navigating Endobronchial Ultrasound


2018, ASME ISPS, San Francisco, California, USA 

In this paper, we proposed a novel electromagnetic targeting system using the rotating magnetic flux concentration method for navigating Endobronchoscopy. This system consists of a magnetic flux emitting coil, a magnetic flux receiving electromagnets array, a 2D model of the bronchial tree, the magnetic flux concentrator embedded on a brush guiding tube which was connected to the guide sheath. When the concentrator in the 2D bronchial tree passes through the air gap between the emitting coil and the receiving electromagnets array, the concentrator concentrates the magnetic flux between the coil and the array The concentrated magnetic flux is subsequently received by the receiving electromagnets array and thus stable voltage output is produced. Furthermore, when the concentrator is rotated, the concentration of the magnetic flux is periodically changed and thereby the voltage output is periodically changed. By analyzing the voltage changes, the location of the concentrator (as well as guide tube and sheath) is targeted. According to the experimental results, the system successfully targets the location of the guide sheath in the 2D model of the bronchial tree.

Journal Article

Passive Magnetic-Flux-Concentrator Based Electromagnetic Targeting System for Endobronchoscopy

Sensors 2019, 19, 5105

In this paper, we demonstrate an innovative electromagnetic targeting system utilizing a passive magnetic-flux-concentrator for tracking Endobronchoscopy used in the diagnosis process of lung cancer tumors/lesions. The system consists of a magnetic-flux emitting coil, a magnetic-flux receiving electromagnets-array, and high permeability silicon-steel sheets rolled as a collar (as the passive magnetic-flux-concentrator) fixed in a guide sheath of an Endobronchoscopy. The emitting coil is used to produce AC magnetic-flux, which is consequently received by the receiving electromagnets-array. Due to the electromagnetic-induction, a voltage is induced in the receiving electromagnets-array. When the Endo bronchoscopy's guide sheath (with the silicon-steel collar) travels between the emitting coil and the receiving electromagnets-arrays, the magnetic flux is concentrated by the silicon-steel collar and thereby the induced voltage is changed. Through analyzing the voltage–pattern change, the location of the silicon–steel collar with the guide sheath is targeted. For testing, a bronchial-tree model for training medical doctors and operators is used to test our system. According to experimental results, the system is successfully verified to be able to target the Endobronchoscopy in the bronchial-tree model. The targeting errors on the x-, y- and z-axes are 9 mm, 10 mm, and 5 mm, respectively.

Autobiography

My name is Jia-En Chen, I graduate from the National Chiao Tung University Department of Mechanical Engineering. My study focuses on the Passive Magnetic-Flux-Concentrator-Based Electromagnetic Targeting System integrate into Induction Heating Hyperthermia for Endobronchoscopy. During the research, I've tried simulation using ANSYS Maxwell. When I have free time, I like to play table tennis. Through practice, now I'm in school team. With teem work, we've won several champions. 

履歷
個人檔案

Jia-En Chen(Samuel)


Responsible, Passion, Persevere
Birth Day:1995/07/26
Email:[email protected]
Phone:0912024459

Education



National Chiao Tung University Department of Mechanical Engineering

Nano Engineer Lab

National Sun Yat-sen University Department of  Mechanical and Electro-Mechanical Engineering

Work Experience

Dynamic Class TA  •  

National Chiao Tung University Department of Mechanical Engineering

Feb. 2018 - Jun. 2018


Skill

Professional Field


  • Programming:C, Matlab
  • Apply Software:LabView,  ANSYS Maxwell
  • Professional Field:Statics, Dynamics, Electromagnetic(master degree needed)

Language


  • English (TOEIC 825)

Conference Paper

Novel Electromagnetic Targeting System for Navigating Surgery in Endobronchoscopy


2018 IEEE International Magnetics Conference (INTERMAG), Singapore

Nowadays, lung cancer is one of the common cancers around the world. To increase the survival rate of the patient, early diagnosis is necessary. To achieve this, bronchoscopists usually use Endobronchial Ultrasound for navigating surgery in Endobronchoscopy. However, because the bronchoscopist has to continuously re-navigate/re-target the bronchoscope to collect specimens from the same tumor, the whole navigating/targeting process has to be repeated many times in one surgery. Due to this, navigating/targeting the bronchoscope to correct tumor is still a time-consuming process. Therefore, a more accurately tumor-targeting approach is needed to significantly save time in navigating surgery. To address this issue, recently researchers combined electromagnetic (magnetic-sensor-based)targeting technology with conventional endobronchial ultrasound as a hybrid targeting approach to achieve a more accurate real-time tumor-targeting in Endobronchoscopy . However, when comparing conventional bronchoscope, the bronchoscope with magnetic sensor is more expensive and less compatible. Thus, a cheaper and compatible electromagnetic targeting technology is required. Recently, some researchers demonstrated electromagnetic induction/ magnetic-interaction approaches to target distal screw-hole in intramedullary interlocking-nail surgery We think that these targeting approaches can be modified to develop as a new, cheaper, and compatible electromagnetic targeting technology for general Endobronchoscopy. Hence, in this paper, we demonstrate the electromagnetic targeting system for Endobronchoscopy.


A Novel Targeting System Using Magnetic-Rotating  Method for Navigating Endobronchial Ultrasound


2018, ASME ISPS, San Francisco, California, USA 

In this paper, we proposed a novel electromagnetic targeting system using the rotating magnetic flux concentration method for navigating Endobronchoscopy. This system consists of a magnetic flux emitting coil, a magnetic flux receiving electromagnets array, a 2D model of the bronchial tree, the magnetic flux concentrator embedded on a brush guiding tube which was connected to the guide sheath. When the concentrator in the 2D bronchial tree passes through the air gap between the emitting coil and the receiving electromagnets array, the concentrator concentrates the magnetic flux between the coil and the array The concentrated magnetic flux is subsequently received by the receiving electromagnets array and thus stable voltage output is produced. Furthermore, when the concentrator is rotated, the concentration of the magnetic flux is periodically changed and thereby the voltage output is periodically changed. By analyzing the voltage changes, the location of the concentrator (as well as guide tube and sheath) is targeted. According to the experimental results, the system successfully targets the location of the guide sheath in the 2D model of the bronchial tree.

Journal Article

Passive Magnetic-Flux-Concentrator Based Electromagnetic Targeting System for Endobronchoscopy

Sensors 2019, 19, 5105

In this paper, we demonstrate an innovative electromagnetic targeting system utilizing a passive magnetic-flux-concentrator for tracking Endobronchoscopy used in the diagnosis process of lung cancer tumors/lesions. The system consists of a magnetic-flux emitting coil, a magnetic-flux receiving electromagnets-array, and high permeability silicon-steel sheets rolled as a collar (as the passive magnetic-flux-concentrator) fixed in a guide sheath of an Endobronchoscopy. The emitting coil is used to produce AC magnetic-flux, which is consequently received by the receiving electromagnets-array. Due to the electromagnetic-induction, a voltage is induced in the receiving electromagnets-array. When the Endo bronchoscopy's guide sheath (with the silicon-steel collar) travels between the emitting coil and the receiving electromagnets-arrays, the magnetic flux is concentrated by the silicon-steel collar and thereby the induced voltage is changed. Through analyzing the voltage–pattern change, the location of the silicon–steel collar with the guide sheath is targeted. For testing, a bronchial-tree model for training medical doctors and operators is used to test our system. According to experimental results, the system is successfully verified to be able to target the Endobronchoscopy in the bronchial-tree model. The targeting errors on the x-, y- and z-axes are 9 mm, 10 mm, and 5 mm, respectively.

Autobiography

My name is Jia-En Chen, I graduate from the National Chiao Tung University Department of Mechanical Engineering. My study focuses on the Passive Magnetic-Flux-Concentrator-Based Electromagnetic Targeting System integrate into Induction Heating Hyperthermia for Endobronchoscopy. During the research, I've tried simulation using ANSYS Maxwell. When I have free time, I like to play table tennis. Through practice, now I'm in school team. With teem work, we've won several champions.